General data
| Mounting type | Flush |
|---|---|
| Special type | Linearized Factor 1 |
| Measuring distance Sd | 0 … 8 mm |
| Sensitivity | 1,25 V/mm |
| Repeat accuracy | 0.03 mm |
| Adjustment | External Teach-in |
| Teach | 1-point analog, 2-point analog, factory reset |
| Linearity error | ± 70 µm |
| Temperature drift | ± 3 % (Full Scale: S = 0 ... 6 mm) ± 5 % (Full Scale: S = 0 ... 8 mm) |
| Teach-Feedback | LED yellow |
Electrical data
| Voltage supply range +Vs | 12 … 36 VDC |
|---|---|
| Current consumption max. (no load) | 15 mA |
| Output circuit | Analog 0 ... 10 VDC |
| Load resistance | > 4000 Ohm |
| Short circuit protection | Yes |
| Reverse polarity protection | Yes |
Mechanical data
| Design | Cylindrical threaded |
|---|---|
| Material (sensing face) | PBT |
| Housing material | Brass nickel plated |
| Dimension | 18 mm |
| Housing length | 60 mm |
| Connection types | Connector M12 |
| Tightening torque max. | 40 Nm |
Ambient conditions
| Operating temperature | -25 … +75 °C |
|---|---|
| Protection class | IP 67 |
Data sheet
Quickstart
Quickstart – IR18.D08F-F60.UA1E.7BO
DE/EN/FR
Operating instructions
Certificates / approvals
DoC / CoC - IR018
EN/DE/BG/CZ/DK/ES/FI/FR/GR/HU/IT/LT/LV/NL/NO/PL/PT/RO/SK/SI