VS XC800M20X00IP
Products / Vision sensor

VS XC800M20X00IP

Vision sensor
Order #
11166808
Part #
BAU.11166808
Lifecycle
Active
← Back to Products

Sensor

Resolution 1600 × 1200 px
Sensor type 1/1.8″ CCD, monochrome

Electrical & Environment

Power consumption Max. 42 W (with I/O and lighting)
Operating temperature +5 … +55 °C T = measurement point
Humidity 0 … 90 % (non-condensing)
Flash memory size 2000 Mbit Flash S34ML02G100BHI0000

Interface & Connectivity

Process interface PROFINET (CC-A) EtherNet/IP<sup>™</sup> TCP/UDP (Ethernet)

Mechanical

Width 53 mm (without lens/tube)
Height 99.5 mm (without lens/tube)
Depth 49.8 mm (without lens/tube)
Weight ≤ 300 g (without lens/tube)
Material housing: aluminum cover glass XC tube: PMMA
Protection class IP 67 (with tube)

Compliance

Conformity CE RoHS KC (R-R-BkR-VeriSens-XC-IP) UL recognized

Other

Illumination external, available as accessory
Illumination connection direct (integrated <i>VeriFlash</i><sup>®</sup> flash controller)
High-resolution mode max. 21 inspections per second
High-speed mode (limited resolution) max. 35 inspections per second
Number of jobs (products) ≤ 255
Features per job 32
Signal processing Baumer <i>FEX</i><sup>®</sup> 4.0
Defect image memory 4
Lens C-mount
Nominal voltage power supply 24 V ±25 %
Nominal voltage power supply (add-on) Class 2 according to NEC / protection class III
Nominal voltage power supply (info) The device is intended for supply from an isolated limited power source according to UL61010-1, 3rd ed cl. 9.4 or a limited energy source according to UL60950-1 or Class 2 according to NEC.
Inputs 8 … 30 V (polarity protected)
Digital inputs 5 inputs trigger job selection external teach-in encoders (CH-A, CH-B) 500 kHz
Outputs PNP I<sub>peak</sub> = 100 mA and I<sub>eff</sub> = 50 mA (short-circuit proof)
Digital outputs 5 outputs Pass / Fail Flash Sync Alarm Camera Ready Output Enable
Initial setup Ethernet (10BASE-T / 100BASE-TX)
Visualization configurable web interface with <i>MultiViewer</i> function
Storage temperature -20 … +70 °C
Vibration load IEC 60068-2-6 IEC 60068-2-64
Mechanical shock resistance EN 60068-2-27
Barcode 2/5 Industrial 2/5 Interleaved Codabar Code 39 Code 93 Code 128 PharmaCode EAN 8 EAN 13 UPC-A UPC-E GS1 DataBar GS1 128
Matrix code DataMatrix (ECC 200) GS1-DataMatrix QR-Code PDF417
Font Sans serif fonts (or similar to: OCR-A,OCR-B, Arial, Tahoma, Courier, Univers, Frutiger, Verdana, Bookman, Franklin Gothic Book, Garamond, Nimbus San T, Palatino, Linotype, Sylfaen, Times New Roman, DIN 1451 Mittelschrift, DIN Neuzeit Grotesk LT Light, ITC Officina Sans, LT Book, Farrington 7B etc.) Dot Print Characters: A-Z a-z 0-9 + - . : / ( )
Part location Part location on contours Part location on edges Part location on circle Part location on text line
Geometry Distance circle angle count edges point position edge characteristics
Feature comparison count contour points contour comparison brightness contrast area size count areas pattern comparison find object positions
Identification Barcode Matrix code Text
Voltage 12 V DC or 24 V DC (permanent) 24 V DC or 48 V DC (pulsed)
Current I<sub>max</sub> = 800 mA at 24 V DC (permanent) (±10 %, at least ± 100 mA, at 25 °C) I<sub>max</sub> = 4 A at 48 V DC (pulsed) (+10/-20 %, at least ± 100 mA, at 25 °C)
Flash time max. 1 ms (Duty Cycle max. 1:10)

Quickstart

Electrical connection M12 / 12-pin, A-coded (on device)

Electrical connection illumination M8 / 4-pin (on device)

Ethernet connection M12 / 4-pin (on device)

Drawings

📐
VS XC800M20X00IP / STEP
📐
XC Tube / STEP
📐
XC Tube Modul 6mm / STEP
📐
XC Tube Modul / STEP
XC-800.png
XC-800.png